Products

OZONE GENERATORS FOR AIR MOD.ARPUR 10 / 20G

Characteristics

TECHNICAL CHARACTERISTICS - ARPUR 10G / H

 Ozone output 10,000 mg / h (10G / h)
 AC voltage input 220 V 50 / 60H
 Power - 50 W
 Consumption - 0.050kW / h
 Size - 15cmx17cmx20cm
 Weight - 2.0Kg
 Installation of the device on behalf of the customer.

APPLICATION
 Enough for volume - 30 m³ to disinfect the environment.
Polluting agents procedure the mandatory treatment time is changed.

TECHNICAL CHARACTERISTICS - ARPUR 20G / H
 Ozone output 20,000 mg / h (20G / h)
 AC voltage input 220 V 50 / 60H
 Power - 80 W
 Consumption - 0.080kW / h
 Size - 15cmx17cmx20cm
 Weight - 2.0Kg
 Installation of the device on behalf of the customer.

APPLICATION
 Sufficient for volume - 61 m³ to disinfect the environment.
Polluting agents procedure the mandatory treatment time is changed.

Description

EXPRESSLY PROHIBITED THE HUMAN PRESENCE IN THE ENVIRONMENT DURING OPERATION

While expressing our thanks, we are honored to have chosen
present device and we are pleased to welcome you to the growing line of M&GT products Electronics Ltd.
We ask that you carefully read all the instructions contained in this manual, specially prepared so you can get to know your equipment.
The ozone generator, eliminates unpleasant odors such as cigarette smell, animal smell, smell of food, mold, mites and micro-organisms such as bacteria, viruses, protozoa, mites, among others.
With a compact, portable and powerful design, the ozone generator is an electronic device that makes the advanced cleaning of environments without using chemicals and without leaving secondary residues.


SAFETY INFORMATION
• Before installing, read this manual carefully.
• Install the equipment according to the instructions in this manual.


WARNING!!!!!
KEEP THE APPLIANCE OUT OF CHILDREN'S REACH.
• Inhaling ozone in high concentrations can cause serious damage to health.
• Never leave HUMAN BEINGS in the environment when applying an air disinfection application.


IMPORTANT INFORMATIONS:
This generator under normal operating conditions, being installed correctly, does not present any risk to operators. In order to avoid the possibility of risks to health and the environment, observe the following precautions:
- Do not start this generator until you have read all the instructions contained in this manual.
- Only start the production of ozone gas after the installation is complete (electrical).
- In case of use in the environment (rooms, apartments, ICUs, cinemas and theaters), make sure that all ́
the windows and doors are closed and there is no human or domestic animal in that location.
- Use the following routine for air disinfection:
Connect the power plug to the outlet with 220V AC voltage;
Turn the TIMER at the desired time, immediately leave the room, closing it completely. After time enough to achieve the desired result the device will automatically turn off, wait 30 minutes and then open the entrance door and windows to ventilate and after that the room will be released.
In Brazil, the Ministry of Labor, through the Regulatory Norm (NR 15), indicates, in Annex 11, maximum exposure of 0.08 ppm (parts per million) for working hours of up to 48 hours per week and further classifies ozone with the highest degree of unhealthiness in the case of its characterization.
However, in unoccupied areas, with no people present, ozone at levels above the allowed by the standards can be an excellent decontaminant, acting on microorganisms and volatile gases, in addition to controlling odors, acting on their own source. The EPA (Environmental Protection Agency), like OSHA (Ocuppational Safety and Healthy Administration), is not opposes the use of ozone gas indoors since it is completely uninhabited.


CABINET COOLING:
The ARPUR-5/10 / 20G / H generator is air-cooled by means of the fan.
obstructed or placed near a wall that obstructs them, thus avoiding overheating of their electrical and electronic components.
Keep obstacles at least 15 cm from your rear. The ambient temperature of the installation location should not exceed 45 degrees Celsius, sheltered from the weather, dust and humidity above 70%.


CARE
 Care must be taken that foreign objects do not fall into the ARPUR-5/10 / 20G / H device,
especially metallic objects.
 Do not try to make repairs internally, send M&GT service equipment.
 When using for air sterilization, WITHOUT HUMAN PRESENCE, indoors, wait
at least for thirty (40) minutes, after automatic shutdown of the device, let it ventilate and
after it is released for access by people in the environment.


INSTALLATION INSTRUCTIONS
 Install the device in high places (above the material to be sterilized) and keep 15 cm
obstacles, for better efficiency in treating ambient air.
 The device has a DE timer from 1 to 60 minutes.
 Connect the equipment to electrical power - equipment voltage 220V AC
 The device switches ON THROUGH THE TIMER (turn the timer until the desired time) and the shutdown is
will do automatically after the programmed time.

Workshops: small, medium, large and bus cars, eliminating odors from cigarette, mold and etc;
Offices: purification of the air system;
Schools: purification of the air system;
Kitchens: elimination of fried odors, spoiled food, etc;
Pet-shops: elimination of residual animal odors;
Bathrooms: elimination of urine and feces odors;
Homes: eliminating odors, allergenic substances in the rooms, bringing you a better quality of life
and your family;
Clinics: maintaining the sanitized and deodorized environment;

 

WARRANTY: Against manufacturing defects for 6 months from the date of purchase. Not us we are responsible for defects arising from accidents or connections at wrong voltages, falls and handling inappropriate.


MAINTENANCE AND REPAIRS:
Corrective maintenance can only be done by M&GT. This does not imply LOSS OF WARRANTY. The above guarantee is only for the customer who purchased the generator, accompanied by the corresponding invoice, the period is counted from the date of issue of that invoice. If you need corrective maintenance, proceed as follows: Send an email to megtcx@gmail.com or WathsApp to (54) 9-9170-9998, reporting what happened and if possible with photos. According to what M&GT guides, securely pack the generator, issue the delivery invoice for repair or copy of the purchase note
(in case of an individual), send by MAIL or by a carrier you trust, and then inform by email or WathsApp (54) 9-9170-9998 the tracking number of the Post Office or the name of the carrier
and phone number.
OPENING HOURS - MON. FRIDAY FROM 8: 00HS TO 11: 00HS - 13: 00HS AS 17: 00HS
PREVENTIVELY: Always keep the cabinet clean, using a damp cloth to maintain its appearance.- Under normal operating conditions, that is, in a non-humid environment.